Factors that Determined a Positive Response to Resynchronization Therapy in Patients With Chronic Heart Failure and Cardiac Dyssynchrony. One Center Experience

Author:

Postol A. S.1ORCID,Neminushchiy N. M.2ORCID,Antipov G. N.1ORCID,Ivanchenko A. V.1ORCID,Lyashenko V. V.1ORCID,Kalinin D. A.1ORCID,Kotov S. N.1ORCID,Vygovsky A. B.1ORCID,Shneider Yu. A.1ORCID

Affiliation:

1. Federal Center of High Medical Technologies, Kaliningrad

2. Sechenov First Moscow State Medical University, Moscow

Abstract

Aim. To evaluate the efficacy of cardiac resynchronization therapy (CRT) in patients with chronic heart failure (CHF) associated with cardiac dyssynchrony and to identify the factors that influence the CRT efficacy.Material and methods. This retrospective study included 155 patients after implantation of CRT devices. The CRT devices with a built-in cardioverter-defibrillator (CRT-D) and without it (CRT-P) were implanted in 139 (89.7%) and 16 (10.3%) patients, respectively. The follow-up period was 52.37±35.94 months. Based on the study results, two groups of patients were formed depending on the presence of a clinical response to CRT, responders and non-responders. The factors that influenced the clinical response to CRT were studied. The effect of the baseline state of patients on the effect of therapy was assessed. The need for CRT optimization and a possibility of using electrocardiographic criteria for that purpose were studied. Modern devices and leads for CRT, their functional capabilities and their influence on the CRT efficacy were characterized. Statistical analysis was performed with an IBM SPSS Statistics 21.0 (Chicago, USA) package.Results. CRT implantation with the left ventricular lead placement according to the traditional technique, through the coronary sinus, was successful in 130 (87.9%) patients. Difficulties with the left ventricular lead placement were noted in 13 (8.3%) patients when other techniques were used. After 6 months, a hemodynamic and clinical response was observed in 112 (72.2%) patients, and no positive response in 43 (27.8%). The increase in left ventricular ejection fraction in the responder group was more than 21.8±3.7%, which was associated with an improvement of the 6-minute walk test results. Th clinical response was significantly influenced by the possibility of stimulation from the basal parts of the heart; the use of more modern devices for CRT and quadripolar left ventricular leads; timely CRT optimization; and persistent dyssynchrony in non-responders. During the follow-up period, 34 (21.9%) patients died. The death rate in the non-responder group was significantly higher than in the responder group, 18 (41.3%) vs. 16 (14.3%), p=0.001. The main cause of death in the group of non-responders was CHF. Heart transplantation was performed in 3 (1.9%) patients.Conclusion. CRT increases the life span and improves the quality of life in patients with CHF and cardiac dyssynchrony. There was a group of patients with no benefit from CRT in this study. Modern devices allow increasing the number of patients who benefit from CRT. Periodic optimization of CRT is necessary. When optimizing CRT, it is possible to use electrocardiographic criteria of effectiveness: duration of the QRS complex and changes in the position of the electrical axis of the heart.

Publisher

APO Society of Specialists in Heart Failure

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3