The Incidence and Possible Predictors of Coronary Restenosis

Author:

Filatova A. Yu.1,Romasov I. V.1,Potekhina A. V.1,Osokina A. K.1,Noeva E. A.1,Arefieva T. I.1,Barabanova E. A.2,Merkulov E. V.1,Samko A. N.1,Provatorov S. I.1

Affiliation:

1. National Cardiology Research Center, Moscow

2. I. M. Sechenov First Moscow State Medical University

Abstract

Objective. Assess time and possible predictors of restenosis after the implantation of first- and second-generation coronary stents and bare metal stents (BMSs) in patients with stable coronary artery disease after elective coronary stenting.Materials and Methods. From 2010 to 2014, 3,732 (2,897 males, 60 [53; 68] years old) patients with stable exertional angina of functional class I–III underwent coronary stenting. From 2014 to 2017, 1,487 (1,173 males and 314 females) patients returned. Repeat coronary angiography was performed in 699 patients.Results. A total of 644 first-generation stents, 5,321 second-generation stents, and 473 BMSs were implanted. During the control coronary angiography, contrasting was repeated for 193 first-generation stents, 899 second-generation stents, and 77 BMSs. Restenosis (stenosis of 50 % or more in the previously stented segment) was detected in 28 (14 % of angiographic control) first-generation drug-eluting stents, 94 (10 %) second-generation drug-eluting stents, and 21 (27 %) BMSs. Patients with BMS restenosis returned significantly earlier than patients with restenosis of the first- and second-generation drug-eluting stents (11 [6, 27] months vs. 32 [11; 48]) months and 24 [12; 42] months, respectively; p<0.05). The initial and repeat levels of high-sensitivity C-reactive protein (hs-CRP) were higher in patients with restenosis (2.2 [1.2, 5.0] mg / L vs. 2.1 [1.0, 4.6] mg / L, respectively; p> 0.05) than in patients without restenosis (2.0 [0.9, 4.2] mg / L vs. 1.9 [0.7, 3.5] mg / L respectively, p>0.05). Blood levels of hs-CRP ≥2 mg / L according to receiver operating characteristic curve (ROC) analysis at return visit were used as a predictor to identify restenosis of stents with a diameter <3 mm and a length >25 mm – area under the curve (AUC) 0.67 (95 % confidence interval (CI) 0.51–0.84), p <0.05, odds ratio 3.7 (95 % CI 1.1–12.1), p<0.05. Stent type had a significant effect on the time to restenosis in the survival analysis (p<0.0005).Conclusion. The time from coronary stenting to the return visit of patients presenting with restenosis after the implantation of first- and second-generation drug-eluting stents is consistent; median time of the return visit of patients with restenosis of the first-generation stents was 2–3 years after coronary stenting. Blood levels of hs-CRP ≥2 mg / L at the return visit is a predictor of restenosis of stents with a diameter <3 mm and a length >25 mm.

Publisher

APO Society of Specialists in Heart Failure

Subject

Cardiology and Cardiovascular Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3