An Investigation on the Possible Radioactive Contamination of Environment during a Steam-Line Break Accident in a VVER-1200 Nuclear Power Plant

Author:

Khan Abid Hossain1ORCID,Ghosh Angkush Kumar2ORCID,Rahman Md Sumon1ORCID,Ahmed S M Tazim1ORCID,Karmakar C L1ORCID

Affiliation:

1. Department of Industrial and Production Engineering, Jashore University of Science and Technology, Jashore, 7408 Bangladesh

2. Department of Mechanical Engineering, Khulna University of Engineering and Technology, Khulna, 9203 Bangladesh

Abstract

In this work, the possibility of contamination of environment by radioactive elements due to a steam-line break accident has been investigated for a VVER-1200 type nuclear power plant. Personal Computer Transient Analyzer (PCTRAN) has been used to generate the response data of the plant safety systems numerically for an accidental condition like such. A break of 1000 cm2 in the A-loop of the steam line has been considered. A break of the size is considered a “Large Break”, which is believed to be responsible for multiple serious accidents in the past. Also, it has also been assumed that off-site AC power supply is unavailable. Simulations were run for time duration of 300 seconds since most of the safety features of the plant should respond within 50 seconds from the initiation of the accident. Results show that SCRAM is initiated within 22.5 seconds from the emergence of the break, which limited the peak core thermal power to around 105% of the nominal value. The peak temperatures of fuel elements and fuel cladding are recorded to be around 1850oC and 620oC respectively, which are both within the safety limits. The pressure inside reactor pressure vessel has not undergone any significant changes, showing no sign of failure. Again, the pressure inside the reactor containment building is kept within 2.5 bar by the safety systems, indicating that there is no possibility of containment failure due to over-pressure. Finally, the readings from radiation monitor show that there is no noticeable release of radioactive elements to the environment during the accident. Therefore, it may be concluded that the release of radioactive elements in the surrounding environment during a steam-line break accident is very unlikely provided that the plant safety systems are fully functional.

Publisher

Enviro Research Publishers

Subject

General Environmental Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3