Affiliation:
1. School of Life Sciences, Swami Ramanand Teerth Marathwada University, Nanded, 431606 Maharashtra India .
2. Department of Microbiology, District Buldana, Shri Shivaji Science College Chikhli, 443201 Maharashtra India .
Abstract
The potential of bacteria for the treatment of municipal wastewater was investigated in present study. Total eight bacterial isolates were used for this study that showed growth on wastewater agar medium. These isolates were identified on the basis of morphological and biochemical test and identified as Bacillus licheniformis NW16, Pseudomonas aeruginosa NS19, Pseudomonas sp. NS20, Planococcus salinarum NS23, Stenotrophomonas maltophilia NS21, Paenibacillus sp. NW9, Paenibacillus borealis NS3 and Aeromonas hydrophilia NS17. The B. licheniformis NW16 showed highest potential to reduce all parameter under study than other isolates except Ammonical nitrogen. B. licheniformis NW16 and Aeromonas hydrophilia NS17 showed maximum reduction (42.86%) in BOD each. B. licheniformis NW16 and Paenibacillus sp. NW9 showed 82.76% and 81.61% reduction in COD respectively. B. licheniformis NW16, P. salinarum NS23 and Aeromonas hydrophilia NS17 showed reduction in nitrate ranging from 17.36%-63.64%. All the isolates have potential to reduced phosphate from 17.55% -72.3%. B. licheniformis NW16, Ps. aeruginosa NS19, Pseudomonas sp. NS20, Paenibacillus sp. NW9 and Aeromonas hydrophilia NS17 showed reduction in TSS ranging from 42.69%-79.94%. B. licheniformis NW16, Ps. aeruginosa NS19, Pseudomonas sp. NS20, S. maltophilia NS21 and Paenibacillus sp. NW9 showed reduction in TDS ranging from 14%-81.4%.
Publisher
Enviro Research Publishers
Subject
General Environmental Science
Reference28 articles.
1. Rathore DS, Rai N, Ashiya P, Physico Chemical Analysis of Water of Ayad River at Udaipur, Rajasthan (India). International Journal of Innovative Research in Science, Engineering and Technology 3(4): 11660- 11667 (2014).
2. Tamil selvi A, Anjugam E, Archana Devi R, Madhan B, Kannappan S, Isolation and characterization of Bacteria from tannery Effluent Treatment plant and their Tolerance to Heavy metals and antibodies. Asian J Exp Biol Sci 3: 34-41 (2012).
3. Azab MS, Waste-waste treatment technology and environmental management using sawdust bio-mixture. JTUSCI 1: 12-23 (2008).
4. Loos R, Carvalho R, Antonio DC, Comero S, Locoro G, Tavazzi S, Paracchini B, Ghiani M, Lettieri T, Blaha L, Jarosova B, Voorspoels S, Servaes K, Haglund P, Fick J, Lindberg RH, EU-wide monitoring survey on emerging polar organic contaminants in wastewater treatment plant effluents. Water Research 47(17): 6475-6487 (2013).
5. Shannon KE, Lee DY, Trevors JT, Beaudette LA, Application of real-time quantitative PCR for the detection of selected bacterial pathogens during municipal wastewater treatment. Sci Total Environ 382: 121-129 (2007).
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献