Author:
Shichman Ittai,Shaked Or,Morgan Samuel,Garceau Simon,Snir Nimrod,Warschawski Yaniv
Abstract
The accuracy of pre-operative digital templating for total hip arthroplasty (THA) using the diseased versus unaffected contralateral joint remains unclear. As such, we devised a study to compare templating precision between the operated hip joint versus the healthy side for patients with osteoarthritis (OA). The study hypothesis was that preoperative templating accuracy of THA on the ipsilateral diseased hip joint would be higher compared to the contralateral healthy hip in patients with OA. We retrospectively reviewed 100 patients who underwent THA for unilateral OA at our center from January 2018 to January 2020. Retrospective preoperative digital templating was performed separately on both the operated hip joint and the healthy contralateral hip joint by a single surgeon who was blinded by the in-situ components sizes. Accuracy of each group was compared to the implanted components. Assessment of the 100 included cases demonstrated superior acetabular component size prediction when templating was performed using the diseased hip compared to the healthy contralateral side (68.0% versus 51.0%, p<0.001). No differences between the cohorts were found regarding templating accuracy of femoral stem sizes (72.0% and 69.0%, p=0.375) or neck offset (73.0% and 69.0%, p=0.289). Templating acetabular cup size using the ipsilateral diseased hip is more accurate than using the contralateral healthy hip in patients with unilateral OA.
Subject
Orthopedics and Sports Medicine,General Medicine,Surgery
Reference30 articles.
1. Bourne RB, Rorabeck CH. Soft tissue balancing : the hip. J Arthroplasty. 2002 ; 17(4 Suppl 1) : 17-22.
2. Dong N, Yang C, Li SQ, Gao YH, Liu JG, Qi X. A novel digital templating methodology for arthroplasty : experience from patients with osteonecrosis of the femoral head. Hip Int. 2017 ; 27(1) : 82-6.
3. Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg. 2009 ; 52(1) : 6-11.
4. Sariali E, Mauprivez R, Khiami F, Pascal-Mousselard H, Catonne Y. Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res. 2012 ; 98(2) : 151-8.
5. Wang Q, Xiao J, Zhu L, Zhao X, Liu Z, Wang J, et al. Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty. Orthop Traumatol Surg Res. 2017 ; 103(3) : 341-7.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献