Abstract

Determination of the factors causing the development of aseptic instability of endoprosthesis components is one of the main tasks of modern traumatology and orthopedics. It is important from a scientific and medical point of view to carry out physical and mathematical modeling of the distribution of load forces and their moments on the femoral component of a hip endoprosthesis. The purpose of the study: to conduct a physical and mathematical modeling of the distribution of load forces on the femoral component of a hip endoprosthesis under real conditions of incomplete axially symmetrical contact of the femoral component of the endoprosthesis and the femur, when the surface of the lower end of the endoprosthesis is not in contact with the surface of the bone. In the work, mathematical modeling of the distribution of point load forces and their moments on the contact surface between the femoral endoprosthesis stem and the bone marrow canal of the femur in real conditions is carried out. For qualitative estimates of point distributions of the load force, based on the analysis of previous results, an estimated empirical formula was obtained for these distributions: g(λ,λ1)=Р(λ,λ1) / 140λ7/2, in which the pressure Р(λ,λ1) is taken in kilograms per square centimeter (kg/cm2), and the point force g(λ,λ1) is in kilograms (kg). It was determined that the best, from the point of view of minimizing the harmful mechanical impact of the prosthesis on the femur, is the situation when the length of the prosthesis stem is not less than half the length of the femur (λ≥0.5). In this case, the values of the point load forces do not exceed 0.1 kg, at least for the length of the area of real contact, which is not less than half the length of the prosthesis stem (λ1≥0.5λ). It has been proven that the use of a prosthesis stem that is less than a third of the length of the femur is not advisable. Since already at the length of the prosthesis stem, which is 30 % of the length of the femur (λ=0.3), point loads increase rapidly and can reach from 0.55 to 1.5 kg depending on the length of the contact area. Such point loads are undesirable for the femur in the area of contact with the prosthesis in terms of the integrity of the femur.

Publisher

Vinnytsia National Pyrogov Memorial Medical University

Subject

Industrial and Manufacturing Engineering,Polymers and Plastics,History,Business and International Management

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3