Biomechanical effects of posterior lumbar interbody fusion with vertical placement of pedicle screws compared to traditional placement

Author:

Jiang Ji-Hong,Zhao Chang-Ming,Zhang Jun,Xu Rong-Ming,Chen Lei

Abstract

BACKGROUND The pedicle screw technique is widely employed for vertebral body fixation in the treatment of spinal disorders. However, traditional screw placement methods require the dissection of paraspinal muscles and the insertion of pedicle screws at specific transverse section angles (TSA). Larger TSA angles require more force to pull the muscle tissue, which can increase the risk of surgical trauma and ischemic injury to the lumbar muscles. AIM To study the feasibility of zero-degree TSA vertical pedicle screw technique in the lumbosacral segment. METHODS Finite element models of vertebral bodies and pedicle screw-rod systems were established for the L4-S1 spinal segments. A standard axial load of 500 N and a rotational torque of 10 N/m were applied. Simulated screw pull-out experiment was conducted to observe pedicle screw resistance to pull-out, maximum stress, load-displacement ratio, maximum stress in vertebral bodies, load-displacement ratio in vertebral bodies, and the stress distribution in pedicle screws and vertebral bodies. Differences between the 0-degree and 17-degree TSA were compared. RESULTS At 0-degree TSA, the screw pull-out force decreased by 11.35% compared to that at 17-degree TSA (P < 0.05). At 0-degree and 17-degree TSA, the stress range in the screw-rod system was 335.1-657.5 MPa and 242.8-648.5 MPa, separately, which were below the fracture threshold for the screw-rod system (924 MPa). At 0-degree and 17-degree TSA, the stress range in the vertebral bodies was 68.45-78.91 MPa and 39.08-72.73 MPa, separately, which were below the typical bone yield stress range for vertebral bodies (110-125 MPa). At 0-degree TSA, the load-displacement ratio for the vertebral bodies and pedicle screws was slightly lower compared to that at 17-degree TSA, indicating slightly lower stability (P < 0.05). CONCLUSION The safety and stability of 0-degree TSA are slightly lower, but the risks of screw-rod system fracture, vertebral body fracture, and rupture are within acceptable limits.

Publisher

Baishideng Publishing Group Inc.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3