Detection of Vibration Transmitted Through an Object Grasped in the Hand

Author:

Brisben A. J.12,Hsiao S. S.13,Johnson K. O.132

Affiliation:

1. Krieger Mind/Brain Institute;

2. Biomedical Engineering Department, The Johns Hopkins University, Baltimore, Maryland 21218

3. Department of Neuroscience; and

Abstract

Detection of vibration transmitted through an object grasped in the hand. A tool or probe often functions as an extension of the hand, transmitting vibrations to the hand to produce a percept of the object contacting the tool or probe. This paper reports the psychophysical results of a combined psychophysical and neurophysiological study of the perception of vibration transmitted through a cylinder grasped in the hand. In the first part of the psychophysical study, 19 subjects grasped a cylinder, 32 mm diam, with an embedded motor that caused vibration parallel to the axis of the cylinder. The relationship between threshold and frequency was the traditional U-shaped function with a minimum between 150 and 200 Hz. Except a study by Békésy in which subjects grasped a rod that vibrated parallel to the skin surface, thresholds above 20 Hz were lower and the slopes were steeper than any reported previously. Thresholds were <0.01 μm in some subjects. Data from both the psychophysical and the neurophysiological studies suggest that detection performance at frequencies >20 Hz was based on activity in Pacinian afferents. The extreme sensitivity compared with previous reports may have resulted from differences in contact area, direction of vibration, contact force, and the shape of the stimulus probe. The effects of each of these variables were studied. At 40 and 300 Hz (frequencies near the lower and upper end of the Pacinian range) thresholds were 9.8 and 18.5 dB (68 and 88%) lower, respectively, when subjects grasped the cylinder than when a 1-mm-diam probe vibrated perpendicular to the skin. These differences were accounted for as follows: 1) thresholds at a single fingerpad obtained with the large cylindrical surface were, on average, 20 and 60% lower, respectively, than thresholds with the punctate probe; 2) thresholds at the palm were, on average, 15 and 40% lower, respectively, than at the fingerpads; 3) thresholds obtained when the subjects grasped the cylinder averaged 40 and 20% less, respectively, than when the cylinder contacted only the palm; 4) thresholds with the cylinder contacting two fingers were 10 and 30% lower, respectively, than thresholds with the cylinder contacting a single finger; and 5) thresholds with vibration parallel to the skin surface were, on average, 10 and 30% lower, respectively, than thresholds with vibration perpendicular to the skin. Contact force, which was varied from 0.05 to 1.0 N, had no effect.

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

Cited by 178 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. General Sensory System and Taste;From Anatomy to Function of the Central Nervous System;2025

2. Effects of Waveform, Time Delay, and Vibration Axis on the Perception of Vibrotactile Compliance Illusions on Smartphone Touchscreens;International Journal of Human–Computer Interaction;2024-08-09

3. Coding of self and environment by Pacinian neurons in freely moving animals;Neuron;2024-08

4. Skin Sensory Neurons;The Nishinihon Journal of Dermatology;2024-06-01

5. Active electronic skin: an interface towards ambient haptic feedback on physical surfaces;npj Flexible Electronics;2024-05-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3