Affiliation:
1. Cardiovascular Biophysics Laboratory, Washington University, St. Louis, Missouri 63110
Abstract
We sought to extract additional physiological information from the time-dependent left ventricular (LV) pressure contour and thereby gain new insights into ventricular function. We used phase plane analysis to characterize high-fidelity pressure data in selected subjects undergoing elective cardiac catheterization. The standard hemodynamic indexes of LV systolic and diastolic function derived from the time-dependent LV pressure contour could be easily obtained using the phase plane method. Additional novel attributes of the phase plane pressure loop, such as phase plane pressure loop area, graphical representation of the isovolumic relaxation time constant, and quantitative measures of beat-to-beat systolic-diastolic coupling were characterized. The asymmetry between the pressures at which maximum isovolumic pressure rise and pressure fall occur, as well as their load dependence, were also easily quantitated. These results indicate that the phase plane method provides a novel window for physiological discovery and has theoretical and applied advantages in quantitative ventricular function characterization.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
34 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献