Validation of a novel luminal flow velocimeter with video fluoroscopy and manometry in the human esophagus

Author:

Andrews J. M.1,Nathan H.2,Malbert C. H.3,Verhagen M. A. M. T.4,Gabb M.5,Hebbard G. S.1,Kilpatrick D.6,MacDonald S.2,Rayner C. K.1,Doran S.1,Omari T.7,O’Young E.2,Frisby C.2,Fraser R. J.1,Schoeman M.2,Horowitz M.1,Dent J.2

Affiliation:

1. Departments of Medicine,

2. Gastrointestinal Medicine, and

3. Station de Reserches Porcines, Institut National de la Recherche Agronomique, Saint-Gilles 35590, France; and

4. Gastrointestinal Motility Unit, University Hospital, Utrecht 3508, The Netherlands

5. Radiology, Royal Adelaide Hospital, and

6. Department of Cardiology, Royal Hobart Hospital, Hobart, Tasmania 7000, Australia;

7. Department of Gastroenterology, Women’s and Children’s Hospital, Adelaide, South Australia 5000;

Abstract

There is currently no ideal method for concurrently assessing intraluminal pressures and flows in humans with high temporal resolution. We have developed and assessed the performance of a novel fiber-optic laser-Doppler velocimeter, mounted in a multichannel manometric assembly. Velocimeter recordings were compared with concurrent fluoroscopy and manometry following 50 barium swallows in healthy subjects. During these swallows, the velocimeter sensor was situated in either the proximal (24 swallows) or the distal (26 swallows) esophagus. It signaled intraluminal flow following 46 of 50 swallows. A greater mean number of deflections were recorded in the distal compared with the proximal esophagus (4.3 vs. 2.4, P = 0.001). The maximal flow velocity recorded did not differ between the proximal and distal esophagus (76.7 vs. 73.8 mm/s). No velocimeter signals commenced after fluoroscopic lumen occlusion. The velocimeter signals were closely temporally related to fluoroscopic barium flow. Upward catheter movement on swallowing sometimes appeared to cause a velocimeter signal. Manometrically “normal” swallows were no different from “abnormal” swallows in the number and velocity of deflections recorded by the velocimeter. This novel instrument measures intraluminal flow velocity and pressures concurrently, thus enabling direct study of pressure-flow relationships. Flow patterns differed between the proximal and distal esophagus.

Publisher

American Physiological Society

Subject

Physiology (medical),Gastroenterology,Hepatology,Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Nutrient-induced spatial patterning of human duodenal motor function;American Journal of Physiology-Gastrointestinal and Liver Physiology;2001-03-01