Mechanical properties of isolated cardiac myocytes

Author:

Brady A. J.1

Affiliation:

1. Department of Physiology, University of California, School ofMedicine, Los Angeles.

Abstract

A wide variety of techniques have been developed to monitor the mechanical responses of isolated cardiac myocytes. The most successful are those that measure shortening in unattached cells. Because of their relative ease of implementation, edge-detector methods of following cell displacement have become most widespread. Laser diffraction techniques have been applied to the single heart cells, and sophisticated sarcomere imaging systems capable of 2-ms time resolution of shortening responses have also been developed. Active force has been recorded in intact single cells from frog atria; however, the compliance of the force transducers was relatively higher (approximately 5% Lo). (There is an obvious trade-off between transducer sensitivity, which affects noise and drift and compliance.) Some success has been reported with the use of intact rat myocytes supported by suction micropipettes and in guinea pig ventricular myocytes adhering to poly-L-lysine-coated glass beams. With the rat preparation, contractile stress was comparable to that of ventricular muscle, but few cells survived the attachment. In guinea pig myocytes, contractile stress in electrically induced twitches was only approximately 10% of the active stress developed by mammalian trabeculae or papillary muscles at the same temperature (35 degrees C), but, as with the frog atrial transducer, the compliance of the supporting beams was relatively high. Sarcomere uniformity has not been evaluated in these intact preparations. For attachment to the relatively short mammalian cardiac myocytes, the more promising methods that better preserve sarcomere uniformity include double-barreled micropipettes coated with a barnacle adhesive; however, for nonsubmersible transducers, a continuing limitation is the problem of solution surface stability. Unfortunately, the more severe limitation to effective attachment to intact cells is still the extreme sensitivity of the sarcolemma to mechanical stress. The challenge remains to develop an attachment to the intercalated disk such that cell stress can be transferred to the supporting transducers along the normal stress-bearing cellular interface. The ultrastructural and passive mechanical data strongly indicate that although the extracellular collagen limits the extension of cardiac muscle beyond the peak of the active length-tension relation, there is also a substantial cellular component of resistance to extension. Furthermore, this cellular component is related to the cytoskeleton rather than to membranous elements in the cell. The more likely candidates for the longitudinal resting stress-bearing element are titin (connectin) and desmin.(ABSTRACT TRUNCATED AT 400 WORDS)

Publisher

American Physiological Society

Subject

Physiology (medical),Molecular Biology,Physiology,General Medicine

Cited by 169 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3