Exaggerated mechanoreflex in early-stage type 1 diabetic rats: role of Piezo channels

Author:

Grotle Ann-Katrin1,Garcia Elizabeth A.1,Harrison Michelle L.1ORCID,Huo Yu1,Crawford Charles K.1,Ybarbo Kai M.1,Stone Audrey J.1

Affiliation:

1. Department of Kinesiology and Health Education, The University of Texas at Austin, Austin, Texas

Abstract

Recent findings have shown that muscle contraction evokes an exaggerated pressor response in type 1 diabetes mellitus (T1DM) rats; however, it is not known whether the mechanoreflex, which is commonly stimulated by stretching the Achilles tendon, contributes to this abnormal response. Furthermore, the role of mechano-gated Piezo channels, found on thin-fiber afferent endings, in evoking the mechanoreflex in T1DM is also unknown. Therefore, in male and female streptozotocin (STZ, 50 mg/kg)-induced T1DM and healthy control (CTL) rats, we examined the pressor and cardioaccelerator responses to tendon stretch during the early stage of the disease. To determine the role of Piezo channels, GsMTx-4, a selective Piezo channel inhibitor, was injected into the arterial supply of the hindlimb. At 1 wk after STZ injection in unanesthetized, decerebrate rats, we stretched the Achilles tendon for 30 s and measured pressor and cardioaccelerator responses. We then compared pressor and cardioaccelerator responses to tendon stretch before and after GsMTx-4 injection (10 µg/100 ml). We found that the pressor (change in mean arterial pressure) response [41 ± 5 mmHg ( n = 15) for STZ and 18 ± 3 mmHg ( n = 11) for CTL ( P < 0.01)] and cardioaccelerator (change in heart rate) response [18 ± 4 beats/min for STZ ( n = 15) and 8 ± 2 beats/min ( n = 11) for CTL ( P < 0.05)] to tendon stretch were exaggerated in STZ rats. Local injection of GsMTx-4 attenuated the pressor [55 ± 7 mmHg ( n = 6) before and 27 ± 9 mmHg ( n = 6) after GsMTx-4 ( P < 0.01)], but not the cardioaccelerator, response to tendon stretch in STZ rats and had no effect on either response in CTL rats. These data suggest that T1DM exaggerates the mechanoreflex response to tendon stretch and that Piezo channels play a role in this exaggeration.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3