Computational fluid dynamic analysis of flow velocity waveform notching in umbilical arteries

Author:

Tejada-Martínez Andrés E.1,Borberg Christian J.2,Venugopal Resmi1,Carballo Carlos3,Moreno Wilfrido A.4,Quintero Rubén A.5

Affiliation:

1. Department of Civil and Environmental Engineering, University of South Florida, Tampa, Florida;

2. Obstetrics and Gynecology, Allegheny General Hospital, Pittsburgh, Pennsylvania;

3. Departments of 3Mechanical Engineering and

4. Electrical Engineering, University of South Florida, Tampa; and

5. Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Miami, Miami, Florida

Abstract

Umbilical artery Doppler velocimetry waveform notching has long been associated with umbilical cord abnormalities, such as distortion, torsion, and/or compression (i.e., constriction). The physical mechanism by which the notching occurs has not been elucidated. Flow velocity waveforms (FVWs) from two-dimensional pulsatile flows in a constricted channel approximating a compressed umbilical cord are analyzed, leading to a clear relationship between the notching and the constriction. Two flows with an asymmetric, semi-elliptical constriction are computed using a stabilized finite-element method. In one case, the constriction blocks 75% of the flow passage, and in the other the constriction blocks 85%. Channel width and prescribed flow rates at the channel inflow are consistent with typical cord diameters and flow rates reported in the literature. Computational results indicate that waveform notching is caused by flow separation induced by the constriction, giving rise to a vortex (core) wave and associated eddies. Notching in FVWs based on centerline velocity (centerline FVW) is directly related to the passage of an eddy over the point of measurement on the centerline. Notching in FVWs based on maximum cross-sectional velocity (envelope FVW) is directly related to acceleration and deceleration of the fluid along the vortex wave. Results show that notching in envelope FVW is not present in flows with less than a 75% constriction. Furthermore, notching disappears as the vortex wave is attenuated at distances downstream of the constriction. In the flows with 75 and 85% constriction, notching of the envelope FVW disappears at ∼3.8 and ∼4.3 cm (respectively) downstream of the constriction. These results are of significant medical importance, given that envelope FVW is typically measured by commercial Doppler systems.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3