Urinary oxygen tension: a clinical window on the health of the renal medulla?

Author:

Evans Roger G.1,Smith Julian A.2,Wright Christopher3,Gardiner Bruce S.4,Smith David W.4,Cochrane Andrew D.2

Affiliation:

1. Department of Physiology,

2. Department of Surgery (Monash Medical Centre) and

3. Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Australia;

4. School of Computer Science and Software Engineering, The University of Western Australia, Perth, Australia

Abstract

We describe the determinants of urinary oxygen tension (Po2) and the potential for use of urinary Po2 as a “physiological biomarker” of the risk of acute kidney injury (AKI) in hospital settings. We also identify knowledge gaps required for clinical translation of bedside monitoring of urinary Po2. Hypoxia in the renal medulla is a hallmark of AKI of diverse etiology. Urine in the collecting ducts would be expected to equilibrate with the tissue Po2 of the inner medulla. Accordingly, the Po2 of urine in the renal pelvis changes in response to stimuli that would be expected to alter oxygenation of the renal medulla. Oxygen exchange across the walls of the ureter and bladder will confound measurement of the Po2 of bladder urine. Nevertheless, the Po2 of bladder urine also changes in response to stimuli that would be expected to alter renal medullary oxygenation. If confounding influences can be understood, urinary bladder Po2 may provide prognostically useful information, including for prediction of AKI after cardiopulmonary bypass surgery. To translate bedside monitoring of urinary Po2 into the clinical setting, we require 1) a more detailed knowledge of the relationship between renal medullary oxygenation and the Po2 of pelvic urine under physiological and pathophysiological conditions; 2) a quantitative understanding of the impact of oxygen transport across the ureteric epithelium on urinary Po2 measured from the bladder; and 3) a simple, robust medical device that can be introduced into the bladder via a standard catheter to provide reliable and continuous measurement of urinary Po2.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 47 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3