Carotid and aortic baroreflexes of the rat: II. Open-loop frequency response and the blood pressure spectrum

Author:

Dworkin Barry R.12,Tang Xiaorui1,Snyder Alan J.3,Dworkin Susan1

Affiliation:

1. Department of Behavioral Science,

2. The Neuroscience Program,

3. Department of Surgery, Artificial Organs, Pennsylvania State University College of Medicine, Hershey, Pennsylvania 17033

Abstract

To determine the relationship between blood pressure (BP) variability and the open-loop frequency domain transfer function (TF) of the baroreflexes, we measured the pre- and postsinoaortic denervation (SAD) spectra and the effects of periodic and step inputs to the aortic depressor nerve and isolated carotid sinus of central nervous system-intact, neuromuscular-blocked (NMB) rats. Similar to previous results in freely moving rats, SAD greatly increased very low frequency (VLF) (0.01–0.2 Hz) systolic blood pressure (SBP) noise power. Step response-frequency measurements for SBP; interbeat interval (IBI); venous pressure; mesenteric, femoral, and skin blood flow; and direct modulation analyses of SBP showed that only VLF variability could be substantially attenuated by an intact baroreflex. The −3-dB frequency for SBP is 0.035–0.056 Hz; femoral vascular conductance is similar to SBP, but mesenteric vascular conductance has a reliably lower and IBI has a reliably higher −3-dB point. The overall open-loop transportation lag, of which ≤0.1 s is neural, is ≈1.07 s. Constrained algebraic solution, over a range of frequencies, of the pre- and postSAD endogenous noise spectra and the independently determined relative frequency and absolute lag measurements was used to calculate the absolute gain for the open-loop TF. The average gain at 0.02 Hz, the frequency of maximum sensitivity, was 1.47 (95% confidence interval = ±0.48), which agrees well with estimates for the dog reversible sinus. We found that, in the NMB rat, the effects of SAD on the BP noise spectrum were accounted for by the open-loop properties of the baroreflex.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3