Meal-contingent intestinal lymph sampling from awake, unrestrained rats

Author:

Arnold Myrtha1,Dai Yunting1,Tso Patrick2,Langhans Wolfgang1

Affiliation:

1. Physiology and Behavior Laboratory, Institute of Food, Nutrition and Health, Swiss Federal Institute of Technology, (ETH) Zurich, Switzerland; and

2. Department of Pathology, University of Cincinnati, Cincinnati, Ohio

Abstract

Standard procedures for intestinal lymph collection involve continuous, quantitative drainage of the lymph fluid in anesthetized or restrained animals that are often euthanized within 48 h. We here describe a novel technique for the nonocclusive cannulation of the major intestinal lymph duct in rats that allows for repetitive in vivo sampling of intestinal lymph from unrestrained, awake, and ad libitum-fed animals. The distinctive feature of this novel technique is that a 5- to 7-mm long piece of Vialon tubing (OD/ID: 0.8/0.7 mm) with a small hole in its wall is first implanted into the major intestinal lymph duct for stabilization. The tapered tip (OD: ≈0.1 mm) of the catheter is then inserted into the hole of the tubing and fixed in place with a polyamid suture and a drop of tissue glue. In our hands, catheters implanted this way remain patent for up to 6 wk after surgery. In an initial experiment we collected lymph from six adult rats before (0) and 15, 30, 45, 60, 75, 90, 120, and 180 min (120 μl, each) after the onset of isocaloric (12.5 kcal) low-fat (LF) or high-fat (HF) test meals and measured active glucagon-like peptide-1 (GLP-1). Intestinal lymphatic GLP-1 concentration increased ( P < 0.05) from ≈4 pmol/l (0 min) to a peak of 33 ± 6 (means ± SE) or 22 ± 4 pmol/l at 15 (HF) or 30 min (LF) after meal onset and gradually returned to baseline levels by 180 min. With this new technique fewer animals are required to generate physiologically relevant data for various aspects of gastrointestinal physiology that involve the lymphatic system. Furthermore, the advantage of this system is that the animal can act as its own control when the effect of different experimental protocols is tested.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3