Aerobic system analysis based on oxygen uptake and hip acceleration during random over-ground walking activities

Author:

Beltrame Thomas12ORCID,Hughson Richard L.1

Affiliation:

1. Faculty of Applied Health Sciences, University of Waterloo, Waterloo, Ontario, Canada; and

2. Conselho Nacional de Desenvolvimento Científico e Tecnológico, Brasília, Distrito Federal, Brazil

Abstract

Deteriorated aerobic response to moderate exercise might precede the manifestation of clinical symptoms of noncommunicable diseases. The purpose of the current study was to verify that the use of current wearable technologies for analysis of pulmonary oxygen uptake (V̇o2) dynamics during a pseudorandom ternary sequence (PRTS) over-ground walking protocol is a suitable procedure for the investigation of the aerobic response in more realistic settings. A wearable accelerometer located at the hip assessed the magnitude of the input changes delivered to the aerobic system. Eight adults (24 ± 4 yr old, 174 ± 7 cm, and 71.4 ± 7.4 kg) performed two identical PRTS over-ground walking protocols. In addition, they performed on the cycle ergometer two identical pseudorandom binary sequence (PRBS) protocols and one incremental protocol for maximal V̇o2 determination. In the frequency domain, mean normalized gain amplitude (MNG in %) quantified V̇o2 dynamics. The MNG during PRTS was correlated ( r = −0.80, P = 0.01) with the V̇o2 time constant (τ) obtained during cycling. The MNG estimated during PRBS was similar to the MNG estimated during PRTS ( r = 0.80, P = 0.01). The maximal V̇o2 correlated with the MNG obtained during the PRBS ( r = 0.79, P = 0.01) and PRTS ( r = 0.78, P = 0.02) protocols. In conclusion, PRTS over-ground walking protocol can be used to evaluate the aerobic system dynamics by the simultaneous measurement of V̇o2 and hip acceleration. In addition, the aerobic response dynamics from PRBS and PRTS were correlated to maximal V̇o2. This study has shown that wearable technologies in combination with assessment of MNG, a novel indicator of system dynamics, open new possibilities to monitor cardiorespiratory health under conditions that better simulate activities of daily living than cardiopulmonary exercise testing performed in a medical environment.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3