Failure of hemoconcentration during standing to reveal plasma volume decline induced in the erect posture

Author:

Lundvall J.1,Bjerkhoel P.1

Affiliation:

1. Department of Clinical Physiology, Vaxjo Hospital, Sweden.

Abstract

The hypothesis was tested that the hemoconcentration observed during standing provides erroneous information about the induced plasma volume (PV) decline. Male volunteers (n = 10) stood quietly for 15 min after supine rest. On standing arterial hemoglobin (Hb) rose slowly to reach an increase of 5.9 +/- 0.3% (SE) after 15 min. Early after resuming the supine position, Hb increased further to 9.2 +/- 0.5% above control level and then declined gradually. Venous antecubital blood from the left arm supported horizontally at heart level in both the supine and standing positions (no hydrostatic load) showed very similar changes. However, Hb in venous blood collected during standing from the right arm held in the natural dependent position rose much more markedly than that in arterial blood and in venous blood from the horizontal arm (470 +/- 122, 105 +/- 24, and 55 +/- 7% greater increase at 5, 10, and 15 min, respectively). Taken together, these observations indicated that 1) analyses of arterial blood sampled from the standing subject grossly underestimated the prevailing “overall” hemoconcentration and PV decline, a phenomenon ascribed to incomplete mixing of blood between dependent and nondependent regions; 2) arterial blood sampled from the recumbent subject early (60 s) after completion of standing reflected the “true” overall intravascular hemoconcentration, with a calculated PV decline of no less than 511 +/- 27 ml, because the supine position facilitated proper mixing of blood between circulatory compartments; 3) data from common venous sampling from the dependent arm during standing primarily reflected a regional hemoconcentration (fluid loss) in the arm rather than PV decline; and 4) short-term quiet standing caused a more prominent and hemodynamically important decrease in PV than usually believed.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3