Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes

Author:

McCrory Megan A.1,Molé Paul A.1,Gomez Terri D.1,Dewey Kathryn G.1,Bernauer Edmund M.1

Affiliation:

1. Departments of Nutrition and Exercise Science, University of California, Davis, California 95616-8669

Abstract

The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle’s law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtgpred). The validity of using Vtgpred in place of measured Vtg (Vtgmeas) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18–56 yr). There was no significant difference between Vtgmeas and Vtgpred (mean difference ± SE, 53.5 ± 63.3 ml) nor in %BF by using Vtgmeas vs. Vtgpred (0.2 ± 0.2 %BF). On an individual basis, %BF measured by using Vtgmeas vs. Vtgpred differed within ±2.0% BF for 82% of the subjects; maximum differences were −2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (Vr pred vs. Vr meas, respectively). Differences between Vr meas and Vr pred and in %BF calculated by using Vr meas vs. Vr pred were significant (187 ± 46 ml and 1.4 ± 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using Vr meas vs. Vr preddiffered within ±2.0% BF for 46% of the subjects; maximum differences were −2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtgpred for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of Vr pred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtgpred has some application, determining Vtgmeas is relatively simple in most cases. Therefore, we recommend that the use of Vtgmeas remain as standard experimental and clinical practice.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3