Affiliation:
1. Cardiovascular Research Laboratory, Maine Medical Center, Portland, Maine
Abstract
Although blood viscosity varies in relation to shear rate, hematocrit, and temperature, equipment is now available with which it may be measured in respect to each of these variables. A simple, clinically practical technique for such measurement is presented. Blood from 60 normal subjects was adjusted to hematocrits 0, 20, 40, 60, and 80, and the viscosity-shear rate relationships measured at 37.0, 32.0, 27.0, and 22.0 C. The data obtained are presented as a reference for future studies using this method. Technical details are discussed and some deserving areas of application are considered. shear rate; cone-plate viscometer; hematocrit-viscosity relationships; blood, plasma; hematocrit; temperature; blood flow impedance; perfusion; shock; oliguria; dyspnea; coma; heart surgery; blood rheology; metabolism Submitted on May 31, 1963
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
287 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献