Hemodynamic correlates of effective arterial elastance in mitral stenosis before and after balloon valvotomy

Author:

Colin Patrice1,Slama Michel1,Vahanian Alec1,Lecarpentier Yves1,Motté Gilbert1,Chemla Denis1

Affiliation:

1. Service de Cardiologie, Hôpital Antoine-Béclère, 92141 Clamart; Inserm U451-Loa-Ensta-Ecole Polytechnique, 91125 Palaiseau; Service de Cardiologie, Hôpital Tenon, 75970 Paris; and Service de Physiologie Cardio-Respiratoire, Hôpital de Bicêtre, 94275 Le Kremlin-Bicêtre, France

Abstract

Colin, Patrice, Michel Slama, Alec Vahanian, Yves Lecarpentier, Gilbert Motté, and Denis Chemla. Hemodynamic correlates of effective arterial elastance in mitral stenosis before and after balloon valvotomy. J. Appl. Physiol. 83(4): 1083–1089, 1997.—This study had the purpose of documenting the hemodynamic correlates of effective arterial elastance (Ea; i.e., an accurate estimate of hydraulic load) in mitral stenosis (MS) patients. The main hypothesis tested was that Ea relates to the total vascular resistance (R)-to-pulse interval duration ( T) ratio (R/ T) in MS patients both before and after successful balloon mitral valvotomy (BMV). High-fidelity aortic pressure recordings were obtained in 10 patients (40 ± 12 yr) before and 15 min after BMV. Ea value was calculated as the ratio of the steady-state end-systolic aortic pressure (ESAP) to stroke volume (thermodilution). Ea increased after BMV (from 1.55 ± 0.63 to 1.83 ± 0.71 mmHg/ml; P < 0.05). Throughout the procedure, there was a strong linear relationship between Ea and R/ T: Ea = 1.09R/ T − 0.01 mmHg/ml, r = 0.99, P = 0.0001. This ultimately depended on the powerful link between ESAP and mean aortic pressure [MAP; r = 0.99, 95% confidence interval for the difference (MAP − ESAP) from −18.5 to +4.5 mmHg]. Ea was also related to total arterial compliance (area method) and to wave reflections (augmentation index), although to a lesser extent. After BMV, enhanced and anticipated wave reflections were observed, and this was likely to be explained by decreased arterial compliance. The present study indicated that Ea depended mainly on the steady component of hydraulic load (i.e., R) and on heart period (i.e., T) in MS patients.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3