Rate of the Bohr shift in human red cell suspensions

Author:

Craw Margot R.1,Constantine H. P.1,Morello J. A.1,Forster R. E.1

Affiliation:

1. Department of Physiology, Graduate School of Medicine, and Department of Anesthesiology, Schools of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania

Abstract

We have measured the rate at which the O2 tension rises in a partially oxygenated suspension of normal human red cells at 37 C as a result of a sudden rise in CO2 tension (the Bohr shift) in a Hartridge-Roughton rapid reaction apparatus. A Teflon covered platinum electrode was used to measure O2 tension. The rise in O2 tension had an average half time of 0.12 sec following increments of 18–65 mm Hg in CO2 tension in twelve experiments on the blood of three normal individuals. The comparable movement of O2 out of the red cell as a result of a decrease in ambient O2 tension at a constant CO2 tension had an average half time of 0.012 sec in four experiments on the blood from the same three subjects. This suggests that the velocities of the reactions of CO2 are rate-limiting in the Bohr shift. Acetazolamide (10-3 m) slowed the rate of the Bohr shift to less than one-seventh; no measurable change in O2 tension occurred until about 0.03 sec. measurable change in O2 tension occurred until about 0.03 sec. Submitted on July 2, 1962

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 34 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3