Reactive hyperemia unmasks reduced compliance of cutaneous arteries in essential hypertension

Author:

Heron E.1,Chemla D.1,Megnien J. L.1,Pourny J. C.1,Levenson J.1,Lecarpentier Y.1,Simon A.1

Affiliation:

1. Centre de Medecine Preventive Cardiovasculaire-Institut National de la Sante et de la Recherche Medicale U28, Hopital Broussais, Paris, France.

Abstract

To evaluate changes in distal cutaneous arteries during hypertension, we used a noninvasive method to assess the compliance and vascular resistance of the hand radial arteries, mainly distributed to the skin, in 10 normotensive and 10 hypertensive (HT) men. Radial artery diameter and blood velocity were measured by means of pulsed Doppler concomitantly with measurements of finger arterial pressure by photoplethysmography. Hand radial vascular resistance was calculated as the ratio of mean arterial pressure to mean radial blood flow. A simple resistive-capacitive model of large and small arteries of the hand allowed us to evaluate arterial compliance from the exponential slope of finger diastolic pressure decay and vascular resistance. Measurements were made at baseline and during reactive hyperemia after 5 min of complete occlusion of the brachial artery with a pneumatic cuff. Except for pressure, there were no baseline differences between the groups. In normotensive and HT subjects, hyperemia increased radial artery diameter and blood velocity (P < 0.001) and compliance (P < 0.01 and P < 0.05, respectively) and decreased mean pressure (P < 0.01 and P < 0.001, respectively) and resistance (P < 0.001). During hyperemia, the only difference between the groups, except for pressure, was lower compliance in HT subjects (P < 0.01). Moreover, compliance during hyperemia negatively correlated with baseline mean pressure (P = 0.001). Thus hyperemia unmasked reduced compliance in the HT patients but did not show abnormal resistance, suggesting that the elastic properties of the hand skin radial arteries might be more sensitive than their resistive properties to high blood pressure.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3