Abstract
Temperature variations near four common torso skin temperature sites were measured on 17 lightly clad subjects exposed to ambient temperatures of 28, 23, and 18 degrees C. Although variations in skin temperature exceeding 7 degrees C over a distance of 5 cm were observed on individuals, the mean magnitude of these variations was 2-3 degrees C under the coolest condition and less at the warmer temperatures. There was no correlation between the temperature variation and skinfold thickness at a site or with estimations of whole body fat content. These findings imply that errors in mean skin temperature measurement could arise from probe mislocation and/or subcutaneous fat distribution and that the problem becomes more acute with increasing cold stress. However, the magnitudes of these errors cannot be easily predicted from common anthropometric measurements.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
41 articles.
订阅此论文施引文献