Bronchial airway deposition and retention of particles in inhaled boluses: effect of anatomic dead space

Author:

Bennett William D.1,Scheuch Gerhard1,Zeman Kirby L.1,Brown James S.1,Kim Chong1,Heyder Joachim1,Stahlhofen Willi1

Affiliation:

1. Center for Environmental Medicine and Lung Biology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599; GSF-National Research Center for Environment and Health, Institute for Inhalation Biology, D-85758 Neuherberg/Munich, Germany; and Human Studies Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, North Carolina 27771

Abstract

The fractional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the relative volume and size of an individual’s airways. To evaluate the effect of variable anatomic dead space (ADS) on aerosol bolus delivery we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5 μm mean mondispersed aerosol diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at a lung volume of 70% total lung capacity end inhalation. By using filter techniques, aerosol photometry, and gamma camera analysis, we estimated the fraction of the inhaled boluses deposited in intrathoracic airways (IDF). ADS by single-breath N2 washout was also measured from 70% total lung capacity. Results showed that among all subjects IDF was variable (range = 0.04–0.43, coefficient of variation = 0.54) and increased with decreasing ADS ( r = −0.76, P = 0.001, n = 16). We found significantly greater deposition in the left (L) vs. right (R) lungs; mean L/R (ratio of deposition in L lung to R lung, normalized to ratio of L-to-R lung volume) was 1.58 ± 0.42 (SD; P < 0.001 for comparison with 1.0). Retention of deposited particles at 2 h was independent of ADS or IDF. There was significant retention of particles at 24 h postdeposition (0.27 ± 0.05) and slow clearance of these particles continued through 48 h postdeposition. Finally, analysis of central-to-peripheral ratios of initial deposition and 24-h-retention gamma-camera images suggest significant retention of insoluble particles in large bronchial airways at 24 h postdeposition (i.e., 24 h central-to-peripheral ratio = 1.40 ± 0.44 and 1.82 ± 0.54 in the R and L lung, respectively; P < 0.02 for comparison with 1.0). These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Aerosol Therapy and Humidification;Humidification in the Intensive Care Unit;2023

2. Predictions of inter- and intra-lobar deposition patterns of inhaled particles in a five-lobe lung model;Inhalation Toxicology;2021-02-23

3. Regional Lung Deposition: In Vivo Data;Journal of Aerosol Medicine and Pulmonary Drug Delivery;2020-12-01

4. Lung Scintigraphy in the Assessment of Aerosol Deposition and Clearance;Seminars in Nuclear Medicine;2019-01

5. Regional Ventilation Is the Main Determinant of Alveolar Deposition of Coarse Particles in the Supine Healthy Human Lung During Tidal Breathing;Journal of Aerosol Medicine and Pulmonary Drug Delivery;2017-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3