1. Center for Environmental Medicine and Lung Biology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599; GSF-National Research Center for Environment and Health, Institute for Inhalation Biology, D-85758 Neuherberg/Munich, Germany; and Human Studies Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, North Carolina 27771
Abstract
The fractional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the relative volume and size of an individual’s airways. To evaluate the effect of variable anatomic dead space (ADS) on aerosol bolus delivery we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5 μm mean mondispersed aerosol diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at a lung volume of 70% total lung capacity end inhalation. By using filter techniques, aerosol photometry, and gamma camera analysis, we estimated the fraction of the inhaled boluses deposited in intrathoracic airways (IDF). ADS by single-breath N2 washout was also measured from 70% total lung capacity. Results showed that among all subjects IDF was variable (range = 0.04–0.43, coefficient of variation = 0.54) and increased with decreasing ADS ( r = −0.76, P = 0.001, n = 16). We found significantly greater deposition in the left (L) vs. right (R) lungs; mean L/R (ratio of deposition in L lung to R lung, normalized to ratio of L-to-R lung volume) was 1.58 ± 0.42 (SD; P < 0.001 for comparison with 1.0). Retention of deposited particles at 2 h was independent of ADS or IDF. There was significant retention of particles at 24 h postdeposition (0.27 ± 0.05) and slow clearance of these particles continued through 48 h postdeposition. Finally, analysis of central-to-peripheral ratios of initial deposition and 24-h-retention gamma-camera images suggest significant retention of insoluble particles in large bronchial airways at 24 h postdeposition (i.e., 24 h central-to-peripheral ratio = 1.40 ± 0.44 and 1.82 ± 0.54 in the R and L lung, respectively; P < 0.02 for comparison with 1.0). These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
39 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献