Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance

Author:

Lutchen K. R.1,Everett J. R.1,Jackson A. C.1

Affiliation:

1. Department of Biomedical Engineering, Boston University, Massachusetts 02215.

Abstract

In humans, application of the DuBois (DuBois et al. J. Appl. Physiol. 8: 587–594, 1956) six-element model to respiratory transfer impedance (Ztr) data has been proposed as a means to noninvasively estimate airway and tissue properties. This approach requires prior knowledge of alveolar gas compressibility (Cg). With input impedance (Zin), prior knowledge of Cg is not required, but the data do not support a reliable separation of airway from tissue properties. In this study, we investigated the separation of airway and tissue properties when Ztr and Zin data are measured and analyzed simultaneously over a larger frequency range than usual. In 10 healthy adults, we measured Ztr and Zin from 2 to 64 Hz. Zin was measured using both the standard approach with oscillations directly into the airway opening (Zst) and the head generator approach (Zhg) with oscillations applied around the head. With Ztr data alone, we found that the airway resistance and inertance estimates were reliable with only 2- to 32-Hz data and were unaffected by including the additional 32- to 64-Hz data. Conversely, the estimates of tissue resistance and inertance were highly unreliable unless the 32- to 64-Hz data are included. Because of enhanced sensitivity of Ztr to Cg from 32 to 64 Hz, inaccuracies in the assigned Cg will distort the estimated tissue but not airway properties. The Ztr-based parameters predicted Zhg data far better than Zst data, which is consistent with Zhg data being less influenced by upper airway shunting over this frequency range. There was no apparent advantage to combining Ztr and Zhg data during parameter estimation. With Cg unfixed, the estimated Cg was 50–100% higher than expected from an independent measurement of functional residual capacity. These results confirm that Ztr alone can provide a reliable distinction of lumped respiratory airway and tissue properties that are little influenced by upper airway wall shunting but only if 2- to 64-Hz data are analyzed. This distinction, however, requires an accurate prior measurement of Cg, and this requirement cannot be removed by combining Ztr and Zin data.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3