Electrical impedance tomography can monitor dynamic hyperinflation in dogs

Author:

Adler Andy1,Shinozuka Norihiro1,Berthiaume Yves2,Guardo Robert3,Bates Jason H. T.1

Affiliation:

1. Meakins-Christie Laboratories and Department of Biomedical Engineering, McGill University, H2X 2P2;

2. Centre de Recherche Hôtel-Dieu de Montréal and Departement de Médecine, Université de Montréal, H2W 1T8; and

3. Institut de Génie Biomédical, École Polytechnique de Montréal, Montreal, Quebec, Canada H3T 1J7

Abstract

Adler, Andy, Norihiro Shinozuka, Yves Berthiaume, Robert Guardo, and Jason H. T. Bates. Electrical impedance tomography can monitor dynamic hyperinflation in dogs. J. Appl. Physiol. 84(2): 726–732, 1998.—We assessed in eight dogs the accuracy with which electrical impedance tomography (EIT) can monitor changes in lung volume by comparing the changes in mean lung conductivity obtained with EIT to changes in esophageal pressure (Pes) and to airway opening pressure (Pao) measured after airway occlusion. The average volume measurement errors were determined: 26 ml for EIT; 35 ml for Pao; and 54 ml for Pes. Subsequently, lung inflation due to applied positive end-expiratory pressure was measured by EIT (ΔVEIT) and Pao (ΔVPao) under both inflation and deflation conditions. Whereas ΔVPaowas equal under both conditions, ΔVEITwas 28 ml greater during deflation than inflation, indicating that EIT is sensitive to lung volume history. The average inflation ΔVEITwas 67.7 ± 78 ml greater than ΔVPao, for an average volume increase of 418 ml. Lung inflation due to external expiratory resistance was measured during ventilation by EIT (ΔVEIT,vent) and Pes (ΔVPes,vent) and at occlusion by EIT (ΔVEIT,occl), Pes, and Pao. The average differences between EIT estimates and ΔVEIT,occlwere 5.8 ± 44 ml for ΔVEIT,ventand 49.5 ± 34 ml for ΔVEIT,occl. The average volume increase for all dogs was 442.2 ml. These results show that EIT can provide usefully accurate estimates of changes in lung volume over an extended time period and that the technique has promise as a means of conveniently and noninvasively monitoring lung hyperinflation.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3