Rapid determination of glomerular filtration rate by single-bolus inulin: a comparison of estimation analyses

Author:

Sturgeon Cord1,Sam Albert D.1,Law William R.1

Affiliation:

1. Surgery and Research Services, West Side Veterans Affairs Hospital; and Departments of Surgery and of Physiology and Biophysics, University of Illinois Medical Center at Chicago, Chicago, Illinois 60612

Abstract

Rapid measurement of glomerular filtration rate (GFR) by an inulin single-bolus technique would be useful, but its accuracy has been questioned. We hypothesized that reported inaccuracies reflect the use of inappropriate mathematical models. GFR was measured in 14 intact and 5 unilaterally nephrectomized conscious male Sprague-Dawley rats (mean weight 368 ± 12 g) by both single-bolus (25 mg/kg) and constant-infusion techniques (0.693 mg ⋅ kg−1 ⋅ min−1). The temporal decline in plasma inulin concentration was analyzed through biexponential curve fitting, which accounted for renal inulin loss before complete vascular and interstitial mixing. We compared our mathematical model based on empirical rationale with those of other investigators whose studies suggest inaccuracy of single-bolus methods. Our mathematical model yielded GFR values by single bolus that agreed with those obtained by constant infusion [slope = 0.94 ± 0.16 (SE); y intercept = 0.23 ± 0.64; r = 0.82]. In comparison to the data obtained by constant inulin infusion, this method yielded a very small bias of −0.0041 ± 0.19 ml/min. Two previously reported models yielded unsatisfactory values (slope = 1.46 ± 0.34, y intercept = 0.47 ± 1.5, r = 0.72; and slope = 0.17 ± 1.26, y intercept = 17.15 ± 5.14, r = 0.03). The biases obtained by using these methods were −2.21 ± 0.42 and −13.90 ± 1.44 ml/min, respectively. The data indicate that when appropriate mathematical models are used, inulin clearance after single-bolus delivery can be used to measure GFR equivalent to that obtained by constant infusion of inulin. Attempts to use methods of analysis for simplicity or expediency can result in unacceptable measurements relative to the clinical range of values seen.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3