Author:
Knopp T. J.,Kaethner T.,Meyer M.,Rehder K.,Scheid P.
Abstract
Washout of insoluble inert test gases of different diffusivity (He and SF6 or He and Ar) from dog lungs was studied during high-frequency ventilation (HFV). Test gas equilibrium and subsequent washout were performed with HFV, succeeding measurements being performed at different stroke volumes (1.5-2.5 ml/kg body wt), oscillation frequencies (10-30 Hz), and with different lung volumes (32-74 ml X kg-1). Test gas concentrations were continuously measured by a mass spectrometer. The time course of washout could be described as the sum of two exponentials. There were no consistent differences in the time courses of washout between He and SF6 or between He and Ar. It is concluded that gas mixing in the airways during HFV is not significantly limited by diffusion, and this is suggested to apply during HFV to steady-state transport of respiratory gases (e.g., O2 and CO2) as well as to the transient state of inert gas washout.