Pulse pressure response to the strain of the Valsalva maneuver in humans with preserved systolic function

Author:

Hébert Jean-Louis1,Coirault Catherine2,Zamani Karen1,Fontaine Guy3,Lecarpentier Yves1,Chemla Denis1

Affiliation:

1. Service de Physiologie Cardio-Respiratoire, Centre Hospitalier Universitaire de Bicêtre-Assistance Publique-Hôpitaux de Paris, 94 275 Le Kremlin-Bicêtre Cédex;

2. Institut National de la Santé et de la Recherche Médicale U451-Loa-Ensta-Ecole Polytechnique, 91 125 Palaiseau Cédex; and

3. Hôpital Jean-Rostand, 94 200 Ivry-sur-Seine Cédex, France

Abstract

Arterial pulse pressure response during the strain phase of the Valsalva maneuver has been proposed as a clinical tool for the diagnosis of left heart failure, whereas responses of subjects with preserved systolic function have been poorly documented. We studied the relationship between the aortic pulse amplitude ratio (i.e., minimum/maximum pulse pressure) during the strain phase of the Valsalva maneuver and cardiac hemodynamics at baseline in 20 adults (42 ± 14 yr) undergoing routine right and left heart catheterization. They were normal subjects ( n = 5) and patients with various forms of cardiac diseases ( n = 15), and all had a left ventricular ejection fraction ≥40%. High-fidelity pressures were recorded in the right atrium and the left ventricle at baseline and at the aortic root throughout the Valsalva maneuver. Aortic pulse amplitude ratio 1) did not correlate with baseline left ventricular end-diastolic pressure, cardiac index (thermodilution), or left ventricular ejection fraction (cineangiography) and 2) was positively related to total arterial compliance (area method) ( r = 0.59) and to basal mean right atrial pressure ( r = 0.57) (each P < 0.01). Aortic pulse pressure responses to the strain were not related to heart rate responses during the maneuver. In subjects with preserved systolic function, the aortic pulse amplitude ratio during the strain phase of the Valsalva maneuver relates to baseline total arterial compliance and right heart filling pressures but not to left ventricular function.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3