Author:
Melissinos C. G.,Webster P.,Tien Y. K.,Mead J.
Abstract
Nonhomogeneous lungs are predicted to exhibit time dependence of maximal expiratory flow (Vmax): faster regions would contribute more flow early in the expiration, whatever the initial volume, resulting in different Vmax at a given total lung volume, depending on how long flow limitation has been operating. To test this concept a new technique was developed that permits accurate superimposition of Vmax data over small volume intervals. When quick-release interrupted partial curves with similar volume history but different volume of initiation were compared over their late common-volume segments, the volume-history effects could be differentiated from time dependence of the Vmax. Such time dependence was found in 7 of 7 bronchitics, 3 of 5 smokers, and 0 of 14 nonsmokers tested. We conclude that the emptying during the forced expirations is not uniform even in mild disease states and the time dependence of Vmax is a sensitive test of lung inhomogeneity.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
71 articles.
订阅此论文施引文献