Affiliation:
1. Section of Pulmonary and Critical Care Medicine, University of Chicago, Illinois 60637.
Abstract
We studied airway opening in a benchtop model intended to mimic bronchial walls held in apposition by airway lining fluid. We measured the relationship between the airway opening velocity (U) and the applied airway opening pressure in thin-walled polyethylene tubes of different radii (R) using lining fluids of different surface tensions (gamma) and viscosities (mu). Axial wall tension (T) was applied to modify the apparent wall compliance characteristics, and the lining film thickness (H) was varied. Increasing mu or gamma or decreasing R or T led to an increase in the airway opening pressures. The effect of H depended on T: when T was small, opening pressures increased slightly as H was decreased; when T was large, opening pressure was independent of H. Using dimensional analysis, we found that the relative importance of viscous and surface tension forces depends on the capillary number (Ca = microU/gamma). When Ca is small, the opening pressure is approximately 8 gamma/R and acts as an apparent “yield pressure” that must be exceeded before airway opening can begin. When Ca is large (Ca greater than 0.5), viscous forces add appreciably to the overall opening pressures. Based on these results, predictions of airway opening times suggest that airway closure can persist through a considerable portion of inspiration when lining fluid viscosity or surface tension are elevated.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
191 articles.