Effects of transverse fiber stiffness and central tendon on displacement and shape of a simple diaphragm model

Author:

Boriek Aladin M.1,Rodarte Joseph R.1

Affiliation:

1. Pulmonary Section, Department of Medicine, Baylor College of Medicine, Houston, Texas 77030

Abstract

Boriek, Aladin M., and Joseph R. Rodarte. Effects of transverse fiber stiffness and central tendon on displacement and shape of a simple diaphragm model. J. Appl. Physiol. 82(5): 1626–1636, 1997.—Our previous experimental results (A. M. Boriek, S. Lui, and J. R. Rodarte. J. Appl. Physiol. 75: 527–533, 1993 and A. M. Boriek, T. A. Wilson, and J. R. Rodarte. J. Appl. Physiol. 76: 223–229, 1994) showed that 1) costal diaphragm shape is similar at functional residual capacity and end inspiration regardless of whether the diaphragm muscle shortens actively (increased tension) or passively (decreased tension); 2) diaphragmatic muscle length changes minimally in the direction transverse to the muscle fibers, suggesting the diaphragm may be inextensible in that direction; and 3) the central tendon is not stretched by physiological stresses. A two-dimensional orthotropic material has two different stiffnesses in orthogonal directions. In the plane tangent to the muscle surface, these directions are along the fibers and transverse to the fibers. We wondered whether orthotropic material properties in the muscular region of the diaphragm and inextensibility of the central tendon might contribute to the constancy of diaphragm shape. Therefore, in the present study, we examined the effects of stiffness transverse to muscle fibers and inextensibility of the central tendon on diaphragmatic displacement and shape. Finite element hemispherical models of the diaphragm were developed by using pressurized isotropic and orthotropic membranes with a wide range of stiffness ratios. We also tested heterogeneous models, in which the muscle sheet was an orthotropic material, having transverse fiber stiffness greater than that along the fibers, with the central tendon being an inextensible isotropic cap. These models revealed that increased transverse stiffness limits the shape change of the diaphragm. Furthermore, an inextensible cap simulating the central tendon dramatically limits the change in shape as well as the membrane displacement in response to pressure. These findings provide a plausible mechanism by which the diaphragm maintains similar shapes despite different physiological loads. This study suggests that changes of diaphragm shape are restricted because the central tendon is essentially inextensible and stiffness in the direction transverse to the muscle fibers is greater than stiffness along the fibers.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3