The Rat Lumbosacral Spinal Cord Adapts to Robotic Loading Applied During Stance

Author:

Timoszyk W. K.1,de Leon R. D.2,London N.3,Roy R. R.3,Edgerton V. R.3,Reinkensmeyer D. J.1

Affiliation:

1. Department of Mechanical and Aerospace Engineering and Center for Biomedical Engineering, University of California, Irvine, 92697-3975;

2. Department of Kinesiology and Nutritional Science, California State University, Los Angeles, California 90032-8162

3. Department of Physiological Sciences and Brain Research Institute, University of California, Los Angeles, 90095-1760; and

Abstract

Load-related afferent information modifies the magnitude and timing of hindlimb muscle activity during stepping in decerebrate animals and spinal cord–injured humans and animals, suggesting that the spinal cord mediates load-related locomotor responses. In this study, we found that stepping on a treadmill by adult rats that received complete, midthoracic spinal cord transections as neonates could be altered by loading the hindlimbs using a pair of small robotic arms. The robotic arms applied a downward force to the lower shanks of the hindlimbs during the stance phase and measured the position of the lower shank during stepping. No external force was applied during the swing phase of the step. When applied bilaterally, this stance force field perturbed the hindlimb trajectories so that the ankle position was shifted downward during stance. In response to this perturbation, both the stance and step cycle durations decreased. During swing, the hindlimb initially accelerated toward the normal, unperturbed swing trajectory and then tracked the normal trajectory. Bilateral loading increased the magnitude of the medial gastrocnemius electromyographic (EMG) burst during stance and increased the amplitude of the semitendinosus and rectus femoris EMG bursts. When the force field was applied unilaterally, stance duration decreased in the loaded hindlimb, while swing duration was decreased in the contralateral hindlimb, thereby preserving interlimb coordination. These results demonstrate the feasibility of using robotic devices to mechanically modulate afferent input to the injured spinal cord during weight-supported locomotion. In addition, these results indicate that the lumbosacral spinal cord responds to load-related input applied to the lower shank during stance by modifying step timing and muscle activation patterns, while preserving normal swing kinematics and interlimb coordination.

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3