Rectification of EMG in low force contractions improves detection of motor unit coherence in the beta-frequency band

Author:

Ward Nicholas J.12,Farmer Simon F.13,Berthouze Luc24,Halliday David M.5

Affiliation:

1. Sobell Department for Motor Neuroscience, Institute of Neurology, University College London, London, United Kingdom;

2. Centre for Computational Neuroscience and Robotics, University of Sussex, Brighton, United Kingdom;

3. National Hospital for Neurology and Neurosurgery, University College London, London, United Kingdom;

4. Institute of Child Health, University College London, London, United Kingdom; and

5. Department of Electronics, University of York, York, United Kingdom

Abstract

Rectification of surface EMG before spectral analysis is a well-established preprocessing method used in the detection of motor unit firing patterns. A number of recent studies have called into question the need for rectification before spectral analysis, pointing out that there is no supporting experimental evidence to justify rectification. We present an analysis of 190 records from 13 subjects consisting of simultaneous recordings of paired single motor units and surface EMG from the extensor digitorum longus muscle during middle finger extension against gravity (unloaded condition) and against gravity plus inertial loading (loaded condition). We directly examine the hypothesis that rectified surface EMG is a better predictor of the frequency components of motor unit synchronization than the unrectified (or raw) EMG in the beta-frequency band (15–32 Hz). We use multivariate analysis and estimate the partial coherence between the paired single units using both rectified and unrectified surface EMG as a predictor. We use a residual partial correlation measure to quantify the difference between raw and rectified EMG as predictor and analyze unloaded and loaded conditions separately. The residual correlation for the unloaded condition is 22% with raw EMG and 3.5% with rectified EMG and for the loaded condition it is 5.2% with raw EMG and 1.4% with rectified EMG. We interpret these results as strong supporting experimental evidence in favor of using the preprocessing step of surface EMG rectification before spectral analysis.

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3