Performance of LH pulse-detection algorithms at rapid rates of venous sampling in humans

Author:

Veldhuis J. D.,Evans W. S.,Rogol A. D.,Drake C. R.,Thorner M. O.,Merriam G. R.,Johnson M. L.

Abstract

To assess the influence of the sampling rate on the quantitative characterization of pulsatile luteinizing hormone (LH) release, we withdrew blood at 4-min intervals for 8 h in five men and at 1-min intervals for 2 h in six other men. For comparative purposes, significant LH pulses were enumerated by three independent, computerized pulse-detection algorithms currently available. Our results indicate that, although the absolute number of LH pulses detected was influenced by the particular algorithm used and the estimate of intra-assay variance, all three analyses yielded increased pulse-frequency estimates at more intensive rates of venous sampling. Moreover, using a fourth, modified pulse-detection algorithm intended to maximize recognition of true-positive LH pulses while minimizing both false-positive and false-negative pulses, we observed that venous sampling at 4- and 1-min intervals exposed 4- and 12-fold more LH pulses, respectively, than could be discerned at conventional sampling rates. At rapid rates of venous sampling, the pattern of LH pulses comprised high-frequency, low-amplitude LH pulsations superimposed on lower-frequency LH peaks. This pattern suggests that the pituitary gland is responsive to high rates of intermittent neural stimulation. Moreover, these observed profiles are consistent with rapid initial rates of LH disappearance and/or distribution that we could demonstrate after intravenous bolus injections of purified LH in hypogonadotropic volunteers. In conclusion, we have compared results from three different pulse-detection algorithms at various rates of venous sampling and demonstrated a critical influence of sampling rate on apparent LH pulse frequency in humans.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology,Endocrinology, Diabetes and Metabolism

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3