Free fatty acid flux measured using [1-11C]palmitate positron emission tomography and [U-13C]palmitate in humans

Author:

Han Qiaojun1,Cao Yanli1,Gathaiya Nicola1,Kemp Bradley J.2,Jensen Michael D.1ORCID

Affiliation:

1. Endocrine Research Unit, Mayo Clinic, Rochester, Minnesota

2. Division of Medical Physics, Department of Radiology, Mayo Clinic, Rochester, Minnesota

Abstract

PET radiopharmaceuticals can noninvasively measure free fatty acid (FFA) tissue uptake. Investigators often use PET scan-derived data to calculate FFA flux. We tested whether the [1-11C]palmitate PET measures of palmitate flux provide results equivalent to a continuous infusion of [U-13C]palmitate. Nine volunteers participated in study 1 to evaluate whether a rapidly (10–20 s) given bolus of [1-11C]palmitate affects calculated flux results. Thirty volunteers participated in study 2, which was identical to study 1 except that the [1-11C]palmitate bolus was given over 1 min. Volunteers in both studies also received a continuous intravenous infusion of [U-13C]palmitate. Plasma palmitate concentrations and enrichment were measured by liquid chromatography-mass spectrometry. The PET/CT images were analyzed on a workstation running PMOD. Palmitate flux was estimated using PET time-activity curve (TAC) data from regions of interest in the left ventricle (LV) and aorta both with and without hybrid TACs that employed the 11CO2-corrected data for the first 5 min and the 11CO2-corrected blood radioactivity for the remainder of the PET scan. Palmitate flux in study 1 measured with PET [1-11C]palmitate and [U-13C]palmitate were not correlated, and the PET [1-11C]palmitate flux was significantly less than the [U-13C]palmitate measured flux. In study 2, the palmitate flux using PET [1-11C]palmitate hybrid LV models provided closer mean estimates of [U-13C]palmitate measured flux. The best PET calculation approaches predicted 64% of the interindividual variance in [U-13C]palmitate measured flux. Palmitate kinetics measured using [1-11C]palmitate/PET do not provide the same palmitate kinetic results as the continuous infusion [U-13C]palmitate approach.

Funder

HHS | NIH | National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)

HHS | U.S. Public Health Service (United States Public Health Service)

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology,Endocrinology, Diabetes and Metabolism

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3