Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor

Author:

Elble R. J.,Randall J. E.

Abstract

Tremor of the extended third digit and bipolar surface and needle electromyograms of the extensor digitorum were recorded from six healthy volunteers for the purpose of elucidating the motor-unit activity responsible for the 8- to 12-Hz component of physiological finger tremor. Tremor was measured with a force transducer during steady voluntary contractions of approximately 200-250 g. The surface EMGs were full-wave rectified and low-pass filtered (-3 dB at 21 Hz), producing the envelope of the surface EMG (the demodulated EMG). Spectral analyses of simultaneous tremor and demodulated EMG records were performed. In four of six subjects, a pronounced 8- to 12-Hz amplitude modulation in the surface EMG was present, and coherency analysis demonstrated that this modulation was strongly correlated with the well-known 8- to 12-Hz tremor. In two subjects this amplitude modulation and tremor were barely detectable, despite the sensitive recording and analysis techniques used in this study. Spectral analysis was performed on 43 motor-unit spike trains. Twenty-two spike trains, having mean firing frequencies in the range of 10-22 spikes/s, produced statistically significant spectral peaks at 8-12 Hz, in addition to the expected spectral peaks at the mean firing frequencies. Of the 22 8- to 12-Hz-producing motor units, 12 had mean firing frequencies in the range of 17-22 spikes/s and exhibited the greatest 8- to 12-Hz activities of all motor units recorded. These motor units displayed transient sequences of double discharges in which interspike intervals (ISIS) of approximately 8-30 ms alternated with ISIS of 60-90 ms, thus producing an 8- to 12-Hz spectral peak. Adjacent ISIS of these motor units were correlated in the range of -0.5 to -0.9. Coherency analyses demonstrated that the 8- to 12-Hz activities of these motor units were correlated with the 8- to 12-Hz finger tremor and surface EMG modulation. The remaining 10 8- to 12-Hz-producing motor units had mean firing frequencies in the range of 10-17 spike/s. Although these motor units did not display the intense double-discharge firing pattern of the more rapidly firing motor units, a tendency toward action potential grouping was present and resulted in 8- to 12-Hz spectral activities which were correlated with the tremor and surface EMG modulation. .. ..

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

Cited by 274 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3