A new anesthesia protocol enabling longitudinal lung-function measurements in neonatal rabbits by micro-CT

Author:

Ferrini Erica1,Leo Ludovica2,Corsi Luisa3,Catozzi Chiara3,Salomone Fabrizio3,Ragionieri Luisa1ORCID,Pennati Francesca4,Stellari Franco Fabio3

Affiliation:

1. Department of Veterinary Science, University of Parma, Parma, Italy

2. Department of Medicine and Surgery, University of Parma, Parma, Italy

3. Chiesi Farmaceutici, S.p.A., Corporate Pre-Clinical Research and Development, Parma, Italy

4. Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy

Abstract

Micro-computed tomography (micro-CT) imaging is an emerging technology with many applications in small animals, for example, the study of pulmonary diseases, although clear guidelines and critical mass of evidence are still missing in the preclinical literature. The neonatal rabbit is a valuable model for studying pulmonary development. However, the longitudinal monitoring of lung function by micro-CT can be challenging. Distinctive datasets corresponding to the end-inspiration and end-expiration phases need to be generated and analyzed to derive lung-functional parameters. The quality of CT scans and the reliability of parameters obtained remain highly dependent on the anesthesia protocol used. Three different anesthetic protocols were tested. The combination of dexmedetomidine 0.25 mg/kg injected intraperitoneally followed by 1% isoflurane was found to facilitate CT imaging at 4 and 11 days after birth. Contrarily, isoflurane and ketamine-xylazine were found unsuitable and thus not investigated further. Total lung volumes significantly increased at day 11 compared with baseline in both respiratory phases, whereas lung tissue remained constant. As expected, functional residual capacity, air-to-tissue ratio, and minute ventilation were significantly increased at day 11 in each animal. Those parameters were correlated with inspiratory capacity, compliance, elastance, and resistance of both respiratory system and tissue component, as measured by flexiVent. Lung development was also evaluated by histomorphometric analyses. In conclusion, we have identified a safe and suitable anesthesia protocol for micro-CT imaging in neonatal rabbits. Moreover, the possibility to longitudinally measure lung function in the same subject dramatically reduced the intraexperimental variability.

Funder

Chiesi Farmaceutici

Publisher

American Physiological Society

Subject

Cell Biology,Physiology (medical),Pulmonary and Respiratory Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3