Delivered dose estimate to standardize airway hyperresponsiveness assessment in mice

Author:

Robichaud Annette1,Fereydoonzad Liah1,Schuessler Thomas F.1

Affiliation:

1. SCIREQ Scientific Respiratory Equipment, Inc., Montreal, Quebec, Canada

Abstract

Airway hyperresponsiveness often constitutes a primary outcome in respiratory studies in mice. The procedure commonly employs aerosolized challenges, and results are typically reported in terms of bronchoconstrictor concentrations loaded into the nebulizer. Yet, because protocols frequently differ across studies, especially in terms of aerosol generation and delivery, direct study comparisons are difficult. We hypothesized that protocol variations could lead to differences in aerosol delivery efficiency and, consequently, in the dose delivered to the subject, as well as in the response. Thirteen nebulization patterns containing common protocol variations (nebulization time, duty cycle, particle size spectrum, air humidity, and/or ventilation profile) and using increasing concentrations of methacholine and broadband forced oscillations ( flexiVent, SCIREQ, Montreal, Qc, Canada) were created, characterized, and studied in anesthetized naïve A/J mice. A delivered dose estimate calculated from nebulizer-, ventilator-, and subject-specific characteristics was introduced and used to account for protocol variations. Results showed that nebulization protocol variations significantly affected the fraction of aerosol reaching the subject site and the delivered dose, as well as methacholine reactivity and sensitivity in mice. From the protocol variants studied, addition of a slow deep ventilation profile during nebulization was identified as a key factor for optimization of the technique. The study also highlighted sensitivity differences within the lung, as well as the possibility that airway responses could be selectively enhanced by adequate control of nebulizer and ventilator settings. Reporting results in terms of delivered doses represents an important standardizing element for assessment of airway hyperresponsiveness in mice.

Funder

SCIREQ Scientific Respiratory Equipment Inc.

Publisher

American Physiological Society

Subject

Cell Biology,Physiology (medical),Pulmonary and Respiratory Medicine,Physiology

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3