Salamander olfactory bulb neuronal activity observed by video rate, voltage-sensitive dye imaging. I. Characterization of the recording system

Author:

Cinelli A. R.1,Neff S. R.1,Kauer J. S.1

Affiliation:

1. Department of Neurosurgery, Tufts Medical School, Boston,Massachusetts, USA.

Abstract

1. In this paper we describe properties of a video imaging system used to acquire voltage-sensitive dye fluorescence signals from the salamander olfactory bulb. Sources of noise in these signals were evaluated in preparations stained with the potentiometric probe RH-414. These were compared with noise levels in signals obtained from a light-emitting diode array designed to stimulate the experimental conditions with light levels similar to those seen in the salamander bulb recordings. These experiments define a number of determinants of video image quality to standardize optical voltage measurements in the salamander olfactory bulb. 2. Images were acquired at video rates using a Newvicon camera in a standard upright microscope and digitized with an eight-bit video frame grabber. 3. Sources of noise related to camera sensitivity, stability of illumination, and mechanical vibration were characterized. Camera dark noise was less than the pixel variability due to photon noise at the camera faceplate. This pixel noise was the limiting factor for discriminating the spatial and temporal properties of the optical responses. 4. No significant noise was found to be related to image digitization, transmission, or readout by the eight-bit frame grabber. Mechanical vibration, light stability, and other sources of noise could be controlled in vitro. In this condition, voltage-sensitive dye signal noise was similar to that in stimulated experiments using the light-emitting diode array. Higher levels of noise were found in vivo; some of this was reduced by sychronizing frame acquisition to the heartbeat. 5. On the basis of photodiode and video measurements, voltage-sensitive dye responses in the salamander olfactory bulb typically fell between 0.75% and 2.5% fractional change of background fluorescence. By appropriately adjusting the video signals before analog-to-digital conversion, we could detect fractional changes of < 0.5%. 6. Both response averaging and low-bandpass spatial filtering improved the signal-to-noise ratios of the images. For small numbers of averaged runs, the best improvement was obtained by low-bandpass spatial filtering. 7. Acquisition of high-spatial resolution video images permitted the use of low-bandpass spatial filters to suppress pixel noise. The degree of spatial enhancement depended on the relationship between the size of the structures of interest, pixel density, and the properties of the convolution filter kernel. This method avoided exposure of the preparation to prolonged illumination and the necessity of applying the large numbers of repeated stimuli required for averaging.

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3