Rectification of the EMG Signal Impairs the Identification of Oscillatory Input to the Muscle

Author:

Neto Osmar Pinto12,Christou Evangelos A.1

Affiliation:

1. Department of Health and Kinesiology, Texas A&M University, College Station, Texas; and

2. Department of Biomedical Engineering, Universidade Camilo Castelo Branco, São Paulo, Brazil

Abstract

Rectification of EMG signals is a common processing step used when performing electroencephalographic–electromyographic (EEG–EMG) coherence and EMG–EMG coherence. It is well known, however, that EMG rectification alters the power spectrum of the recorded EMG signal (interference EMG). The purpose of this study was to determine whether rectification of the EMG signal influences the capability of capturing the oscillatory input to a single EMG signal and the common oscillations between two EMG signals. Several EMG signals were reconstructed from experimentally recorded EMG signals from the surface of the first dorsal interosseus muscle and were manipulated to have an oscillatory input or common input (for pairs of reconstructed EMG signals) at various frequency bands (in Hz: 0–12, 12–30, 30–50, 50–100, 100–150, 150–200, 200–250, 250–300, and 300–400), one at a time. The absolute integral and normalized integral of power, peak power, and peak coherence (for pairs of EMG signals) were quantified from each frequency band. The power spectrum of the interference EMG accurately detected the changes to the oscillatory input to the reconstructed EMG signal, whereas the power spectrum of the rectified EMG did not. Similarly, the EMG–EMG coherence between two interference EMG signals accurately detected the common input to the pairs of reconstructed EMG signals, whereas the EMG–EMG coherence between two rectified EMG signals did not. The frequency band from 12 to 30 Hz in the power spectrum of the rectified EMG and the EMG–EMG coherence between two rectified signals was influenced by the input from 100 to 150 Hz but not from the input from 12 to 30 Hz. The study concludes that the power spectrum of the EMG and EMG–EMG coherence should be performed on interference EMG signals and not on rectified EMG signals because rectification impairs the identification of the oscillatory input to a single EMG signal and the common oscillatory input between two EMG signals.

Publisher

American Physiological Society

Subject

Physiology,General Neuroscience

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3