Effects of lumen volume transit time and pressure on loop of Henle function

Author:

Baines A. D.,Basmadjian D.,Wang B. C.

Abstract

Experiments on Henle's loops were designed to demonstrate the relationships of absorption to distal pressure, transit time, and luminal diameter. Loops of superficial nephrons in hydropenic rats, isolated from the rest of the nephron by oil or solid paraffin blocks, were microperfused at 13.6--20 nl/min. Two samples of fluid were collected from the early distal tubule--one with suction in order to lower distal pressure and reduce luminal volume, the other without suction so that the lumen was distended. Transit times were 30 +/- 2 s without and 19 +/- 2 s with suction. Proximal tubule pressure and perfusion rate were not altered by collection with suction. Absolute absorption, however, descreased from 10.6 +/- 0.4 to 8.4 +/- 0.4 nl/min (P less than 0.001). When salt transport was inhibited by 10(-4) M furosemide in the perfusate, water absorption was 7.8 +/- 0.7 nl/min without suction and 6.1 +/- 0.8 nl/min with suction (P less than 0.01). Computer simulation of Henle's loop shows that these observations cannot be explained by changes in transit time, hydrostatic pressure, or unstirred layers. The observations are simulated when radial fluxes depend on wall thickness and surface area in the descending thin limb.

Publisher

American Physiological Society

Subject

Physiology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3