Nonlinear filter properties of the thick ascending limb

Author:

Layton H. E.1,Pitman E. Bruce2,Moore Leon C.3

Affiliation:

1. Department of Mathematics, Duke University, Durham, North Carolina 27708-0320;

2. Department of Mathematics, State University of New York, Buffalo 14214-3093; and

3. Department of Physiology and Biophysics, State University of New York, Stony Brook, New York 11794-8661

Abstract

A mathematical model was used to investigate the filter properties of the thick ascending limb (TAL), that is, the response of TAL luminal NaCl concentration to oscillations in tubular fluid flow. For the special case of no transtubular NaCl backleak and for spatially homogeneous transport parameters, the model predicts that NaCl concentration in intratubular fluid at each location along the TAL depends only on the fluid transit time up the TAL to that location. This exact mathematical result has four important consequences: 1) when a sinusoidal component is added to steady-state TAL flow, the NaCl concentration at the macula densa (MD) undergoes oscillations that are bounded by a range interval envelope with magnitude that decreases as a function of oscillatory frequency; 2) the frequency response within the range envelope exhibits nodes at those frequencies where the oscillatory flow has a transit time to the MD that equals the steady-state fluid transit time (this nodal structure arises from the establishment of standing waves in luminal concentration, relative to the steady-state concentration profile, along the length of the TAL); 3) for any dynamically changing but positive TAL flow rate, the luminal TAL NaCl concentration profile along the TAL decreases monotonically as a function of TAL length; and 4) sinusoidal oscillations in TAL flow, except at nodal frequencies, result in nonsinusoidal oscillations in NaCl concentration at the MD. Numerical calculations that include NaCl backleak exhibit solutions with these same four properties. For parameters in the physiological range, the first few nodes in the frequency response curve are separated by antinodes of significant amplitude, and the nodes arise at frequencies well below the frequency of respiration in rat. Therefore, the nodal structure and nonsinusoidal oscillations should be detectable in experiments, and they may influence the dynamic behavior of the tubuloglomerular feedback system.

Publisher

American Physiological Society

Subject

Physiology

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Biophysics and biofluid dynamics of primary cilia: evidence for and against the flow-sensing function;American Journal of Physiology-Renal Physiology;2017-09-01

2. Introduction to Mathematical Modeling of Blood Flow Control in the Kidney;Association for Women in Mathematics Series;2017

3. Mathematical modeling of renal hemodynamics in physiology and pathophysiology;Mathematical Biosciences;2015-06

4. Mathematical Modeling of Urea Transport in the Kidney;Subcellular Biochemistry;2014

5. Mathematical modeling of kidney transport;Wiley Interdisciplinary Reviews: Systems Biology and Medicine;2013-07-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3