A simplified method for HPLC determination of creatinine in mouse serum

Author:

Yuen Peter S. T.,Dunn Stephen R.,Miyaji Takehiko,Yasuda Hideo,Sharma Kumar,Star Robert A.

Abstract

Mouse models are frequently used to study renal function. However, mouse serum contains chromagens that interfere with standard picric acid-based assays for serum creatinine. Several alternative methods exist for serum creatinine measurements, including assay by high-performance liquid chromatography (HPLC), but only one has been adapted to mouse serum. Creatinine was measured in serum by acetonitrile deproteinization, followed by isocratic, cation exchange HPLC. The HPLC method was compared with a standard alkaline picrate colorimetric assay, using serum from animals with low-to-moderate renal injury. Acidification of acetonitrile with HCl in the deproteinization step produced variable results, including an extra peak that interfered with integration of the creatinine peak or loss of the creatinine peak. Deproteinizing with acetonitrile alone resulted in a more reliable measurement of serum creatinine, which was validated by a series of known additions of creatinine standard. The HPLC assay was reproducible with coefficients of variation from 1.6 to 5.1%. The picric acid assay overestimated serum creatinine, when directly compared with the HPLC assay. The extent of overestimation, up to sixfold, was greatest at normal (0.1 to 0.2 mg/dl) to moderately elevated (0.5 mg/dl) serum creatinine levels. Mouse serum contains substances that interfere with standard picric acid assays for creatinine. Our new HPLC assay can accurately detect creatinine from 5 μl of mouse serum. These results support the widespread adoption of HPLC to accurately measure serum creatinine in mouse models of renal injury.

Publisher

American Physiological Society

Subject

Physiology

Reference7 articles.

1. Dunn SR, Qi Z, Bottinger EP, Breyer MD, and Sharma K.Utility of endogenous creatinine clearance as a measure of renal function in mice.Kidney Int.In press.

2. Chromatography and electrophoresis of creatinine and other guanidino compounds

3. Jaffé M.über den Niederschlag, welchen Pikrinsäure in normalen Harn erzeugt und über eine neue Reaction des Kreatininis.Z Phys Chem10: 391–400, 1886.

4. Simple high-performance liquid chromatographic method to analyze serum creatinine has several advantages over the Jaffé picric acid reaction as demonstrated with a cimetidine dose response in rhesus monkeys

5. Kasiske BLand Keane WF.Laboratory assessment of renal disease: clearance, urinalysis, and renal biopsy. In:Brenner & Rector's The Kidney, edited by Brenner BM. Philadelphia, PA: Saunders, 1996, p. 1137–1174.

Cited by 120 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3