Airspace Dimension Assessment (AiDA) is a technique to assess lung morphology by measuring lung deposition of inhaled nanoparticles. Nanoparticles deposit in the lungs predominately by diffusion, and average diffusion distances, corresponding to effective airspace radii ( rAiDA), can be inferred from measurements of particle recovery after varied breath holds. Also, particle recovery after a 0-s breath hold ( R0) may hold information about the small conducting airways. This study investigates rAiDA at different volumetric sample depths in the lungs of healthy subjects. Measurements were performed with 50-nm polystyrene nanospheres on 19 healthy subjects aged 17–67 yr. Volumetric sample depths ranged from 200 to 5,000 ml and breath-hold times from 5 to 20 s. At the examined volumetric sample depths, rAiDA values ranged from ~200–600 μm, which correspond to dimensions of the bronchiolar and the gas-exchanging regions of the lungs. R0 decreased with volumetric sample depth and showed more intersubject variation than rAiDA. Correlations were found between the AiDA parameters, anthropometry, and lung function tests, but not between rAiDA and R0. For repeated measurements on 3 subjects over an 18-mo period, rAiDA varied on average within ± 7 μm (± 2.4%). The results indicate that AiDA has potential as an efficient new in vivo technique to assess individual lung properties. The information obtained by such measurements may be of value for lung diagnostics, especially for the distal lungs, which are challenging to examine directly by other means. NEW & NOTEWORTHY This is the first study to measure effective airspace radii ( rAiDA) at volumetric sample depths 200–5,000 ml in healthy subjects by Airspace Dimension Assessment (AiDA). Observed rAiDA were 200–600 μm, which corresponds to airspaces for the bronchiolar and the gas-exchanging regions around airway generation 14–17. rAiDA correlated with lung function tests and anthropometry. Measurements of rAiDA on 3 subjects over 11–18 mo were within ± 7 μm.
Funder
The Swedish Research Council
The Crafoord foundation
The Swedish Governmental Agency for Innovation Systems
The ERA-NET project EuroNanoMed2
The Swedish Heart and Lung Foundation
The Swedish Research Council for Health, Working Life nad Welfare
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献