Regional measurement of canine skeletal muscle blood flow by positron emission tomography with H2 15O

Author:

Fischman Alan J.123,Hsu Hongbing13,Carter Edward A.425,Yu Yong M.425,Tompkins Ronald G.425,Guerrero J. Luis4,Young Vernon R.42,Alpert Nathaniel M.1

Affiliation:

1. Division of Nuclear Medicine, Department of Radiology, and

2. Shriners Burns Institute, Boston 02114; and Departments of

3. Radiology and

4. Surgical Service, Massachusetts General Hospital, and

5. Surgery, Harvard Medical School, Boston, Massachusetts 02115

Abstract

Positron emission tomography (PET) with H2 15O was used as an in vivo, relatively noninvasive, quantitative method for measuring regional blood flow to hindlimb skeletal muscle of anesthetized dogs. A hydrooccluder positioned on the femoral artery was used to reduce flow, and high-flow states were produced by local infusion of adenosine. Three to four measurements were made in each animal. Approximately 40 mCi of H2 15O were injected intravenously, and serial images and arterial blood samples were acquired over 2.5 min. Data analysis was performed by fitting tissue and arterial blood time-activity curves to a modified, single-compartment Kety model. The model equation was also solved on a pixel-by-pixel basis to yield maps of regional skeletal muscle blood flow. After each PET determination, flow was measured with radioactive microspheres. Results of the PET measurements demonstrated that basal flow to hindlimb skeletal muscle was 3.83 ± 0.36 ml · min−1 · 100 g−1(mean ± SE). This value was in excellent agreement with the microsphere data, 3.73 ± 0.32 ml · min−1 · 100 g−1( P = 0.69, not significant). Adenosine infusion resulted in flows as high as 30 ml · min−1 · 100 g−1, and the PET and microsphere data were highly correlated over the entire range of flows ( r 2 = 0.98, P < 0.0001). We conclude that muscle blood flow can be accurately measured in vivo by PET with H2 15O and that this approach offers promise for application in human studies of muscle metabolism under varying pathophysiological states.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3