Random squat/stand maneuvers: a novel approach for assessment of dynamic cerebral autoregulation?

Author:

Barnes Sam C.1,Ball Naomi1,Panerai Ronney B.12,Robinson Thompson G.12,Haunton Victoria J.12

Affiliation:

1. Department of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom; and

2. National Institute for Health Research, Biomedical Research Unit in Cardiovascular Sciences, Clinical Sciences Wing, Glenfield Hospital, Leicester, United Kingdom

Abstract

Squat/stand maneuvers (SSM) have been used to assess dynamic cerebral autoregulation (dCA), but always at a fixed frequency (FF). This study aimed to assess the use of random-frequency (RF) SSMs as a stimulus for measuring dCA and determine the reproducibility of FF and RFSSMs. Twenty-nine healthy volunteers [19 male, mean age 23.0 (4.9) yr] completed the study; 11 returned for a repeat visit (median 45 days). Heart rate, beat-to-beat blood pressure, middle cerebral artery (MCA) blood flow velocity, end-tidal CO2, and angle of the squat movement were measured. Subjects underwent four recordings: 5 min sitting, 5 min standing, FFSSMs (0.05Hz), and RFSSMs. Subjects were asked to rate the degree of exertion experienced while performing these maneuvers. Twenty-nine subjects completed the protocol; nine data sets were deemed unsuitable for further analysis. Mean ARI of 6.21 (1.04) while standing was significantly greater than during the SSMs ( P < 0.01), with mean (SD) ARI during the FF and RFSSMs being 5.16 (1.43) and 5.37 (1.21), respectively. However, no significant difference was found between the ARI estimates from the two SSMs ( P = 0.856) or for each of the four recordings between the two visits ( P = 0.645). RFSSMs were found to be significantly less tiring than FFSSMs ( P < 0.01). In conclusion, RFSSMs are an effective and noninvasive method of assessing dCA. There is no difference in the ARI estimates in comparison with FFSSMs. Although FFSSMs have been well tolerated previously, RFSSMs are preferred by healthy subjects and thus may be better tolerated by a patient population in a clinical setting. NEW & NOTEWORTHY RFSSMs provided comparable estimates of autoregulatory indices to FFSSMs. Instead of point estimates at the driven frequency, RFSSMs generate a broader power spectrum of changes in arterial blood pressure and cerebral blood flow velocity, allowing direct comparison with spontaneous fluctuations through transfer function analysis. Moreover, random-frequency SSMs are preferred by participants. They are a novel tool by which larger blood pressure oscillations can be elicited for the reliable measurement of dynamic cerebral autoregulation.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3