Abstract

Measurement of lung clearance index (LCI) by multiple breath washout (MBW) is a sensitive method for monitoring lung disease in patients with cystic fibrosis (CF). To compare nitrogen MBW (N2-MBW) and sulfur hexafluoride MBW (SF6-MBW), we connected these two gas analysis systems in series to obtain truly simultaneous measurements, with no differences other than the gas used. Nonsmoking healthy controls (HC) and subjects with CF were recruited at two institutions. The Exhalyzer-D (for N2-MBW measurement) was connected in series with the Innocor (for SF6-MBW measurement). Subjects washed in SF6 from a Douglas bag with tidal breathing and washed out SF6 and nitrogen with 100% oxygen provided as bias flow. Washout of both gases was continued past the LCI point (1/40th of equilibration concentration) in triplicate. N2-MBW resulted in higher cumulative exhaled volume, functional residual capacity (FRC), and LCI when compared with SF6-derived parameters in HC subjects ( P < 0.0001 for all comparisons). All N2-MBW parameters were also significantly higher than SF6-MBW parameters in subjects with CF ( P < 0.01 for all comparisons). After recalculation with a common FRC, N2-MBW LCI was higher than SF6-MBW LCI in subjects with CF (19.73 vs. 11.39; P < 0.0001) and in HC (8.12 vs. 6.78; P < 0.0001). Adjusting for N2 back diffusion and an offset error in the nitrogen measurement resulted in near complete agreement between the two methodologies. We found significant differences in LCI and FRC measurements using two different gases for MBW. This may have significant implications for the future use and interpretation of LCI data in clinical trials and routine clinical care. NEW & NOTEWORTHY This study provides important insights into the differences between the two techniques used for measuring lung clearance index (LCI): N2 and SF6 multiple breath washout. Differences between measurements made by these two methods in subjects with cystic fibrosis and healthy controls could be explained by nitrogen back diffusion and N2 offset error. This is important for use and interpretation of LCI data as an outcome measure for clinical trials and in routine clinical care.

Funder

Cystic Fibrosis Foundation (CFF)

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3