Abstract
Bioimpedance spectroscopy (BIS) is a technique of interest in the study of human pregnancy because it can assess extracellular (ECW), intracellular (ICW), and total body water (TBW) as ECW plus ICW. The technique requires appropriate resistivity coefficients and has not been sufficiently evaluated during the reproductive cycle. Therefore, in a methodological study, we estimated ECW, ICW, and TBW, by means of BIS, and compared the results with the corresponding estimates obtained by using reference methods. Furthermore, results obtained by means of population-specific resistivity coefficients were compared with results obtained by means of general resistivity coefficients. These comparisons were made before pregnancy, in gestational weeks 14 and 32, as well as 2 wk postpartum in 21 healthy women. The reference methods were isotope and bromide dilution. Average ICW, ECW, and TBW, estimated by means of BIS, were in agreement with reference data before pregnancy, in gestational week 14, and postpartum. The corresponding comparison in gestational week 32 showed good agreement for ICW, whereas estimates by means of BIS were significantly ( P < 0.001) lower than the corresponding reference values for ECW and TBW. Thus the BIS technique, which was based on a model developed for the nonpregnant body, estimated increases in ICW accurately, whereas increases in ECW and TBW tended to be underestimated. Estimates obtained by using population-specific and general resistivity coefficients were very similar. In conclusion, the results indicated that BIS is potentially useful for studies during pregnancy but that further work is needed before it can be generally applied in such studies.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Reference30 articles.
1. Cancer risk in Swedish women: the relation to size at birth
2. Baumgartner R. Electrical impedance and total body electrical conductivity. In: Human Body Composition, edited by Roche A, Heymsfield S, and Lohman T. Champaign, IL: Human Kinetics, 1996, p. 79-107.
3. Letter to the Editor
4. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
5. Cole K. Membranes, Ions and Impulses: A Chapter of Classical Biophysics. Berkley, CA: University of California Press, 1972.
Cited by
45 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献